Mindray BA88A

December 12th, 2011 | Posted by PSD in Mindray - (Comments Off)

Mindray BA88A

Mindray BA-88A Semi Auto Chemistry Analyzer
Specifications

TESTING ITEM
ALT, AST, ALP, ACP, GGT, a-HBDH, LDH, CK, AMY, TG, TC, HDL-c, LDL-c, UA, UREA, Cr, Glu, TP, Alb, T-BiI, D-Bil, TBA, NH4+, HCO3-, Ca, Mg, CI, Na, K, apoA 1, apoB, Lp(a), C3, C4, IgG, IgA, IgM, HbA1c, Alcohol, Amphetamines, Barbiturates, Benzodiazepine etc.

ANALYSIS METHOD
Endpoint, with or without reagent blank
Endpoint, with sample blank and reagent blank Kinetics, with or without reagent blank
Two point Kinetics / Fixed time, with or without reagent blank
Absorbance
Turbidimetry
Linear and non-linear calibration

LIGHT SOURCE
Tungsten-halogen lamp 6V / 10 W

WAVELENGTH RANGE
Automatic by 8-position filter wheel
8 standard filters: 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm and 670nm.
Bandwidth < 8nm
Stray light: <0.1% @340 nm

PHOTOMETRIC RANGE 0~3.5 ABS
Stability: < 0.005A/20min @340nm

FLOWCELL
Stainless steel with quartz window
Measuring volume: 32 µl
Optical path: 10mm
Aspiration volume programmable: 200-9000 µl

INPUT
Touch screen with touch pen and popup keypad Mouse or Keyboard via USB

TEMPERATURE CONTROL
By means of Peltier elements
Room temperature, 25ºC, 30ºC or 37ºC

STORAGE
No less than 3000 sample results
No less than 1000 QC results

PRINTER
Built-in thermal printer Supporting HP series

INTERFACE
RS232 serial port supporting data transmission
USB port (2.0), for keyboard, mouse, printer

OPERATING ENVIRONMENT
Temperature: 15ºC-30ºC
Humidity: 35%-85%, no condensation

POWER REQUIREMENT
Wide power supply: AC 100-240V-, 50/60Hz

DIMENSION
430mm x 360mm x 170mm (LxWxH)

WEIGHT
6.8kg

Mindray BS-120

July 12th, 2011 | Posted by PSD in Mindray - (0 Comments)

Mindray BS-120 Auto Analyzer

Mindray BS-120
Auto Chemistry Analyzer

- Discrete, random access, fully automated
- 100 tests per hour, up to 300 tests per hour with ISE
- Up to 26 onboard chemistries and 4 ions
- Refrigerated reagent compartment
- Automatic probe cleaning, liquid level detection & collision protection
- 8 wavelengths: 340-670nm
- Automatic dilution for abnormal sample
- External bar code reader (optional)
- Bi-directional LIS interface

Features:
100 tests per hour, up to 300 tests per hour with ISE
Up to 26 onboard chemistries and 4 ions
Refrigerated reagent compartment
Automatic probe cleaning, liquid level detection & collision protection
8 wavelengths: 340-670nm
Automatic dilution for abnormal sample
External bar code reader
Bi-directional LIS interface
Standard Configuration:
BS-120 main unit
Optional:
External Bar Code Reader
ISE Module

Features:
100 tests per hour, up to 300 tests per hour with ISE
Up to 26 onboard chemistries and 4 ions
Refrigerated reagent compartment
Automatic probe cleaning, liquid level detection & collision protection
8 wavelengths: 340-670nm
Automatic dilution for abnormal sample
External bar code reader
Bi-directional LIS interface

Standard Configuration:
BS-120 main unit

Optional:
External Bar Code Reader
ISE Module

Additional Specifications
System Specs

Technical Specifications :
=================
System Function:
- Automatic, discrete, random access
- STAT sample priority
- Throughput:
up to 100 tests/hour (without ISE), up to 300 tests/hour with ISE (4 ions)
- Measuring principles: absorbance photometry, turbidimetry, Ion Selective Electrode technology
- Methodology:
End-point, Fixed-time, Kinetic, optional ISE
- Single/dual reagent chemistries, monochromatic / bichromatic
- Linear / non-linear multipoint calibration
- Programming:
open system with user defined profiles and calculations
Reagent/Sample Handling:
- Reagent/Sample tray: 28 positions for reagents and 8 positions for samples in refrigerated compartment (4~15 )
- Reagent volume: R1: 180~450¼ul, step by 1¼ul
R2: 30~250¼l, step by 1¼ul
- Sample volume: 3~45¼ul, step by 0.5¼ul
- Reagent/Sample probe:
liquid level detection, collision protection and inventory checking
- Probe cleaning:
automatic washing both inside and outside
carry over < 0.1%
- Automatic sample dilution: pre-dilution and post-dilution dilution ratio up to 150
- Dilution vessel: disposable cuvette
External Bar Code Reader (optional):
- Used for sample and reagent programming
- Applicable to various bar code systems including Codabar ITF (Interleaved Two of Five) code128 code39 UPC/EAN Code93
- Capable to communicate with LIS in a bidirectional mode
ISE Module (optional):
- Measuring parameter: K+, Na+,Cl,Li+
- Throughput: up to 200 tests per hour
Reaction System:
- Reaction rotor: rotating tray, containing 40 cuvettes
- Cuvette: optical length 5mm
- Reaction volume: 180~500¼l
- Operating temperature: 37
- Temperature fluctuation: ± 0.1
- Independent mixing probe
Optical System:
- Light Source: Halogen-tungsten lamp
- Wavelength: 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm
- Absorption range: 0 ~3.5Abs (10mm conversion)
Control and Calibration:
- Calibration mode: linear (one point, two points and multi-points), Logit-Log 4P, Logit-Log 5P, spline, exponential, polynomial, parabola
- Control rules: west-guard multi-rule, cumulative sum check, twin plot
Operation Unit:
- Operation system: Windows 2000 Pro with SP4 or Windows XP Pro / Home
- Interface: RS-232
Working Conditions:
- Power Supply: AC200~240V, 50/60Hz, 800W
AC100~130V, 50/60Hz, 800W
- Temperature: 15-30
- Humidity: 35-85%
- Water consumption: 2.5L/hour De-ionized water
- Dimension: bench top, 690mm(W)×570 mm(D)×595 mm (H)
- Weight: 75 kg